Suraj Chemicals logoPart of Suraj Chemicals, Chennai · Manufacturer since 1999 · ISO 9001:2015 certified · FSSAI licensed

Polyelectrolyte for drinking water treatment

Water treatment plants clarify raw river, lake or reservoir water before filtration. A small dose of polymer after the coagulant builds bigger flocs, so clarifiers settle faster and filters run longer.

Sunflocraw waterclear watersettled sludge drawn offDrinking water clarification
Raw water is coagulated, then a small anionic Sunfloc dose grows the floc so it settles before the filters.
Recommended starting grade for drinking water treatment

Sunfloc Anionic HQ for regular plant use, or Anionic MQ for smaller plants and trials. Confirm on your own sample with a free jar test.

  • Where the polymer goes

    After the coagulant (alum or PAC), in the flocculation zone where mixing is gentle, before the clarifier or settling tank.

  • Which charge

    Anionic polyacrylamide is the usual flocculant aid after a metal-salt coagulant. Start with Anionic HQ or Anionic MQ.

  • Dose

    Clean, low-turbidity raw water needs very little polymer; monsoon turbidity needs more. The dosing guide lists typical starting ranges.

  • Tender documents

    We provide the specification sheet and SDS for each grade for your approval file. Ask us for anything else your tender needs.

Related

Where this work clusters

The safety limits that apply

Polymers used in drinking-water treatment are controlled for their residual acrylamide monomer. The US EPA treatment technique in 40 CFR 141.111 limits the monomer to 0.05% in the product when it is dosed at 1 mg/L, or an equivalent combination of lower monomer and higher dose.

The reason is the WHO guideline value for acrylamide in drinking water, 0.5 µg/L. WHO notes that at 1 mg/L dose and 0.05% monomer, the theoretical maximum is 0.5 µg/L, and that conventional treatment does not remove acrylamide, so the polymer is the point to control.

In practice, use a grade certified for potable use where your authority requires it, dose as low as the jar test allows, and keep the dose record. Confirm the requirement with your water authority, since the rules differ between countries and utilities.

Sources: US EPA, 40 CFR 141.111: treatment techniques for acrylamide; WHO, Guidelines for Drinking-water Quality, chapter 12: acrylamide; ASTM D2035-19, Coagulation-Flocculation Jar Test of Water.

Not sure which grade suits your water?

Send us a one-litre sample or describe your process. We test it in our lab free of charge and recommend a grade and starting dose, and quote within 1 business hour.

WhatsApp